Introduced
Underlined text would be added to current law. Struck-through text would be removed.
| 89R958 MP-D | ||
| By: Campbell | S.B. No. 2102 |
| A BILL TO BE ENTITLED | |
| AN ACT | |
| relating to certain energy efficiency performance standards for | |
| residential construction. | |
| BE IT ENACTED BY THE LEGISLATURE OF THE STATE OF TEXAS: | |
| SECTION 1. Chapter 388, Health and Safety Code, is amended | |
| by adding Section 388.0045 to read as follows: | |
| Sec. 388.0045. RESIDENTIAL BUILDING ENERGY EFFICIENCY | |
| PERFORMANCE STANDARDS FOR ATTIC AND RAFTER ASSEMBLIES. (a) This | |
| section applies only to residential construction. | |
| (b) Notwithstanding any requirement contained in an energy | |
| code adopted under Section 388.003(a) or (b), or a local amendment | |
| adopted under Section 388.003(d), pertaining to the insulation of | |
| unvented attic or unvented enclosed rafter assemblies, a local | |
| jurisdiction shall consider an unvented attic or unvented enclosed | |
| rafter assembly to be in compliance with the requirements of the | |
| portion of the energy code administered and enforced by that local | |
| jurisdiction pertaining to the insulation of unvented attic or | |
| unvented enclosed rafter assemblies if: | |
| (1) the attic or rafter assembly is insulated and air | |
| sealed with air impermeable insulation to an R-value of at least: | |
| (A) 20 if the attic or rafter assembly is located | |
| in climate zone 2 or 3; or | |
| (B) 26 if the attic or rafter assembly is located | |
| in climate zone 4; and | |
| (2) the building in which the attic or rafter assembly | |
| is located: | |
| (A) attains a blower door test result of less | |
| than 3.0 ACH50; | |
| (B) has a mechanical ventilation system that does | |
| not rely solely on a negative pressure strategy; | |
| (C) if insulation is installed below the roof | |
| deck and the exposed portion of the roof rafters is not already | |
| covered by air impermeable insulation to an R-value of at least 20 | |
| or 26, as applicable, has the exposed portion of the roof rafters | |
| wrapped in insulation to an R-value of at least 3, except that the | |
| rafters are not required to be covered by insulation if: | |
| (i) the rafters are directly covered by | |
| drywall or finished ceiling; or | |
| (ii) continuous insulation is installed | |
| above the roof deck; and | |
| (D) contains inside the building's thermal | |
| envelope the building's indoor heating, cooling, and ventilation | |
| equipment, including ductwork. | |
| SECTION 2. This Act takes effect September 1, 2025. |
Official text from the Texas Legislature. Formatting has been adapted for reading on Ratifi.