Introduced
Underlined text would be added to current law. Struck-through text would be removed.
| 89R15023 CXP-D | ||
| By: McQueeney | H.B. No. 4627 |
| A BILL TO BE ENTITLED | |
| AN ACT | |
| relating to electric service quality and reliability. | |
| BE IT ENACTED BY THE LEGISLATURE OF THE STATE OF TEXAS: | |
| SECTION 1. Section 36.402, Utilities Code, is amended by | |
| adding Subsection (b-1) to read as follows: | |
| (b-1) Notwithstanding Subsection (b), the commission may | |
| not authorize an electric utility to receive a return on equity for | |
| repaired or replaced damaged infrastructure that the commission | |
| determines the utility should have reasonably anticipated could | |
| have been damaged by the weather-related event or natural disaster. | |
| SECTION 2. Section 38.005(b), Utilities Code, is amended to | |
| read as follows: | |
| (b) The commission may take appropriate enforcement action | |
| under this section, including action against a utility, if any of | |
| the utility's feeders with 10 or more customers has had a SAIDI or | |
| SAIFI average that is more than 200 [ |
|
| system average of all feeders during any two-year period[ |
|
| enforcement action, the commission shall consider: | |
| (1) the feeder's operating and maintenance history; | |
| (2) the cause of each interruption in the feeder's | |
| service; | |
| (3) the duration of each interruption in the feeder's | |
| service; | |
| (4) any action taken by a utility to address the | |
| feeder's performance; | |
| (5) [ |
|
| remediating a feeder's performance; and | |
| (6) [ |
|
| the commission. | |
| SECTION 3. Subchapter A, Chapter 38, Utilities Code, is | |
| amended by adding Section 38.006 to read as follows: | |
| Sec. 38.006. STRUCTURAL INTEGRITY STANDARDS FOR | |
| TRANSMISSION AND DISTRIBUTION POLES. (a) This section applies | |
| only to an electric utility, municipally owned utility, or electric | |
| cooperative that operates transmission or distribution assets. | |
| (b) The commission by rule shall adopt standards for the | |
| structural integrity of transmission and distribution poles. | |
| (c) The standards adopted under this section must: | |
| (1) require an electric utility, municipally owned | |
| utility, or electric cooperative to inspect transmission and | |
| distribution poles and take appropriate remedial action as | |
| necessary on a timeline established by the commission; | |
| (2) account for geographic differences between | |
| regions of the state; | |
| (3) consider national guidelines such as the National | |
| Electrical Safety Code and guidelines developed by the Rural | |
| Utilities Service of the United States Department of Agriculture; | |
| and | |
| (4) establish a classification system to assess the | |
| serviceability of transmission and distribution poles. | |
| (d) Each electric utility, municipally owned utility, and | |
| electric cooperative shall submit to the commission an annual | |
| report on: | |
| (1) the implementation of the utility's or | |
| cooperative's transmission and distribution pole maintenance | |
| schedule; | |
| (2) the results of the utility's or cooperative's | |
| inspection of transmission and distribution poles, including any | |
| remediation or replacement action taken; and | |
| (3) any other information the commission requires. | |
| SECTION 4. The heading to Subchapter E, Chapter 38, | |
| Utilities Code, is amended to read as follows: | |
| SUBCHAPTER E. INFRASTRUCTURE IMPROVEMENT AND MAINTENANCE [ |
|
| SECTION 5. Section 38.101(a), Utilities Code, is amended to | |
| read as follows: | |
| (a) Not later than May 1 of each year, each electric utility | |
| shall submit to the commission a report describing the utility's | |
| activities related to: | |
| (1) identifying areas that are susceptible to damage | |
| during severe weather and hardening transmission and distribution | |
| facilities in those areas; and | |
| (2) vegetation management[ |
|
| [ |
|
| SECTION 6. (a) The changes in law made by this Act to | |
| Section 38.005, Utilities Code, apply only to an enforcement action | |
| initiated by the Public Utility Commission of Texas on or after the | |
| effective date of this Act. An enforcement action initiated before | |
| the effective date of this Act is governed by the law in effect | |
| immediately before the effective date of this Act, and the former | |
| law is continued in effect for that purpose. | |
| (b) In adopting rules under Section 38.006, Utilities Code, | |
| as added by this Act, the Public Utility Commission of Texas shall | |
| allow an electric utility, electric cooperative, or municipally | |
| owned utility to complete any required inspection, remediation, or | |
| replacement of transmission and distribution poles installed | |
| before the effective date of the rules according to a reasonable | |
| timeline approved by the commission that allows the utility or | |
| cooperative to prioritize high-risk transmission and distribution | |
| poles. | |
| SECTION 7. This Act takes effect September 1, 2025. |