Enrolled
Underlined text would be added to current law. Struck-through text would be removed.
| S.B. No. 2835 |
| AN ACT | ||
| relating to municipal regulation of stairway requirements in | ||
| certain apartment buildings. | ||
| BE IT ENACTED BY THE LEGISLATURE OF THE STATE OF TEXAS: | ||
| SECTION 1. Chapter 214, Local Government Code, is amended | ||
| by adding Subchapter I to read as follows: | ||
| SUBCHAPTER I. SINGLE STAIRWAY IN CERTAIN APARTMENT BUILDINGS | ||
| Sec. 214.301. PERMITTED REGULATION OF APARTMENT BUILDING | ||
| STAIRWAY REQUIREMENTS. (a) A municipality may exercise the | ||
| authority under this section regardless of whether the municipality | ||
| has adopted local amendments to the International Building Code | ||
| under Section 214.216(c). | ||
| (b) A municipality may authorize an apartment building to | ||
| have a single stairway only if the building: | ||
| (1) does not have more than six stories above grade | ||
| plane and is not a high-rise as defined by the International | ||
| Building Code, as adopted under Section 214.216; | ||
| (2) does not have more than four dwelling units on any | ||
| floor; | ||
| (3) has automatic sprinkler locations in each interior | ||
| exit stairway, regardless of the type of stairway construction, | ||
| that comply with the requirements prescribed by National Fire | ||
| Protection Association Standard 13 for combustible stairways; | ||
| (4) has: | ||
| (A) an exterior stairway; or | ||
| (B) an interior exit stairway for which the | ||
| doors: | ||
| (i) into the stairway from the interior of | ||
| the building swing into the stairway regardless of the occupant | ||
| load served; and | ||
| (ii) from the interior exit stairway to the | ||
| building exterior swing in the direction of exit travel; | ||
| (5) has interior exit stairway enclosures that: | ||
| (A) have a fire resistance rating of not less | ||
| than two hours; and | ||
| (B) do not contain an elevator opening; | ||
| (6) has on each floor a corridor from each dwelling | ||
| unit entry or exit door to an interior exit stairway, including any | ||
| related exit passageway, that has a fire resistance rating of at | ||
| least one hour; | ||
| (7) does not have more than 20 feet between the entry | ||
| or exit door of a dwelling unit and an exit stairway; | ||
| (8) does not have more than 125 feet of exit access | ||
| travel distance; | ||
| (9) has an exit serving the portion of the building | ||
| that contains two or more dwelling units that does not discharge | ||
| through a portion of the building with a different occupancy | ||
| category, including an accessory parking garage; | ||
| (10) has an exit that terminates in an egress court for | ||
| which the court depth does not exceed the court width, unless it is | ||
| possible to exit the egress court to the public way in either | ||
| direction; | ||
| (11) does not have an opening within 10 feet of an | ||
| unprotected opening into an exit stairway other than a required | ||
| exit door that has a fire resistance rating of at least one hour; | ||
| (12) has emergency escape and rescue openings that | ||
| comply with Section 1031 of the International Building Code as | ||
| adopted under Section 214.216 on each floor served by a single exit; | ||
| (13) does not have an electrical receptacle in an | ||
| interior exit stairway; and | ||
| (14) has an automatic smoke and fire detection system | ||
| that activates an occupant notification system that complies with | ||
| Section 907.5 of the International Building Code as adopted under | ||
| Section 214.216 installed in each: | ||
| (A) common space outside of a dwelling unit; | ||
| (B) laundry room, mechanical equipment room, and | ||
| storage room; | ||
| (C) interior corridor serving a dwelling unit; | ||
| and | ||
| (D) main floor landing or interior or exterior | ||
| exit stairway. | ||
| SECTION 2. This Act takes effect September 1, 2025. | ||
| ______________________________ | ______________________________ | |
| President of the Senate | Speaker of the House | |
| I hereby certify that S.B. No. 2835 passed the Senate on | ||
| May 9, 2025, by the following vote: Yeas 29, Nays 2. | ||
| ______________________________ | ||
| Secretary of the Senate | ||
| I hereby certify that S.B. No. 2835 passed the House on | ||
| May 27, 2025, by the following vote: Yeas 81, Nays 57, two | ||
| present not voting. | ||
| ______________________________ | ||
| Chief Clerk of the House | ||
| Approved: | ||
| ______________________________ | ||
| Date | ||
| ______________________________ | ||
| Governor |