House Committee Report
Underlined text would be added to current law. Struck-through text would be removed.
| 89R22374 DRS-D | ||
| By: Talarico | H.B. No. 5148 | |
| Substitute the following for H.B. No. 5148: | ||
| By: Gates | C.S.H.B. No. 5148 |
| A BILL TO BE ENTITLED | |
| AN ACT | |
| relating to municipal regulation of stairway requirements in | |
| certain multifamily residential buildings. | |
| BE IT ENACTED BY THE LEGISLATURE OF THE STATE OF TEXAS: | |
| SECTION 1. Chapter 214, Local Government Code, is amended | |
| by adding Subchapter I to read as follows: | |
| SUBCHAPTER I. SINGLE STAIRWAY IN CERTAIN MULTIFAMILY RESIDENTIAL | |
| BUILDINGS | |
| Sec. 214.301. DEFINITION. In this subchapter, "multifamily | |
| residential building" means a residential building with a Group R-2 | |
| occupancy under the International Building Code as adopted under | |
| Section 214.216. | |
| Sec. 214.302. APPLICABILITY OF SUBCHAPTER. This subchapter | |
| applies only to a municipality that has a fire department that | |
| employs firefighters who have met the requirements for | |
| certification by the Texas Commission on Fire Protection under | |
| Chapter 419, Government Code. | |
| Sec. 214.303. CERTAIN STAIRWAY REQUIREMENTS PROHIBITED. | |
| (a) Notwithstanding any other law, a municipality may not adopt or | |
| enforce an ordinance, rule, or other regulation requiring a | |
| multifamily residential building to have more than one stairway if | |
| the building meets all other applicable provisions of the adopted | |
| local building codes and: | |
| (1) does not have more than six stories above grade | |
| plane and is not a high-rise as defined by the International | |
| Building Code, as adopted under Section 214.216; | |
| (2) does not have more than four dwelling units on any | |
| floor; | |
| (3) has automatic sprinkler locations in each interior | |
| exit stairway, regardless of the type of stairway construction, | |
| that comply with the requirements prescribed by National Fire | |
| Protection Association Standard 13 for combustible stairways; | |
| (4) has: | |
| (A) an exterior stairway; or | |
| (B) an interior exit stairway for which the | |
| doors: | |
| (i) into the stairway from the interior of | |
| the building swing into the stairway regardless of the occupant | |
| load served; and | |
| (ii) from the interior exit stairway to the | |
| building exterior swing in the direction of exit travel; | |
| (5) has interior exit stairway enclosures that have a | |
| fire resistance rating of not less than two hours; | |
| (6) has on each floor a corridor from each dwelling | |
| unit entry or exit door to an interior exit stairway, including any | |
| related exit passageway, that has a fire resistance rating of at | |
| least one hour; | |
| (7) does not have more than 20 feet between the entry | |
| or exit door of a dwelling unit and an exit stairway; | |
| (8) does not have more than 125 feet of exit access | |
| travel distance; | |
| (9) has an exit serving the portion of the building | |
| with a Group R-2 occupancy under the International Building Code as | |
| adopted under Section 214.216 that does not discharge through a | |
| portion of the building with a different occupancy category, | |
| including an accessory parking garage; | |
| (10) has an exit that terminates in an egress court for | |
| which the court depth does not exceed the court width, unless it is | |
| possible to exit the egress court to the public way in either | |
| direction; | |
| (11) does not have an opening within 10 feet of an | |
| unprotected opening into an exit stairway other than a required | |
| exit door that has a fire resistance rating of at least one hour; | |
| (12) has emergency escape and rescue openings that | |
| comply with Section 1031 of the International Building Code as | |
| adopted under Section 214.216 on each floor served by a single exit; | |
| (13) does not have an electrical receptacle in an | |
| interior exit stairway; and | |
| (14) has an automatic smoke and fire detection system | |
| that activates an occupant notification system that complies with | |
| Section 907.5 of the International Building Code as adopted under | |
| Section 214.216 installed in each: | |
| (A) common space outside of a dwelling unit; | |
| (B) laundry room, mechanical equipment room, and | |
| storage room; | |
| (C) interior corridor serving a dwelling unit; | |
| and | |
| (D) main floor landing or interior or exterior | |
| exit stairway. | |
| (b) This section does not prohibit a municipality from | |
| adopting an ordinance, rule, or other regulation that authorizes a | |
| single stairway for a multifamily residential building that does | |
| not comply with Subsection (a). | |
| Sec. 214.304. NO EFFECT ON PROPERTY OWNERS' ASSOCIATIONS | |
| AND OTHER PRIVATE AGREEMENTS. This subchapter does not prohibit a | |
| property owner from enforcing rules or deed restrictions imposed by | |
| a property owners' association or by other private agreement. | |
| Sec. 214.305. AUTHORIZED REGULATION. Except as provided by | |
| this subchapter, a municipality's height limitations, front | |
| setback requirements, site plan review requirements, and other | |
| zoning requirements that generally apply to the construction of a | |
| multifamily residential building in the area in which the building | |
| is built apply to a multifamily residential building described by | |
| this subchapter. | |
| SECTION 2. This Act takes effect September 1, 2025. |