Ratifi Español Sign in
Ratifi

Federal bills from Congress.gov. State bills from Open States.

SB 1298Session 2025

Building Construction

S 1298 Filed

Underlined text would be added to current law. Struck-through text would be removed.

Florida Senate - 2025 SB 1298 By Senator Simon 3-01007-25 20251298__ 1 A bill to be entitled 2 An act relating to building construction; amending s. 3 455.2124, F.S.; revising applicability of certain 4 provisions relating to an exemption from continuing 5 education requirements; amending s. 468.603, F.S.; 6 revising definitions; amending s. 468.609, F.S.; 7 requiring the Florida Building Code Administrators and 8 Inspectors Board to establish by rule certain 9 internship programs, certain eligibility criteria for 10 one- and two-family dwelling inspector certifications, 11 and a certain application process; amending s. 12 489.103, F.S.; authorizing an owner or, in certain 13 circumstances, an owner’s agent to sign certain 14 documents personally or virtually; revising the form 15 of a required disclosure statement; amending s. 16 489.1195, F.S.; requiring a newly designated 17 qualifying agent to apply to the Department of 18 Business and Professional Regulation for a change of 19 contractor within a certain timeframe in certain 20 jurisdictions; authorizing a business organization to 21 sign a change of contractor form provided by a city or 22 county building department official under certain 23 circumstances; authorizing the owner of a project for 24 which a previous qualifying agent held a building 25 permit to serve a certain notice; requiring a city or 26 county building department official to process a 27 change of contractor in a certain manner upon receipt 28 of a hold harmless affidavit; providing that a 29 qualifying agent designated through a specified change 30 of contractor process is not responsible for certain 31 work; amending s. 713.135, F.S.; revising the 32 threshold contract value amount at which a building 33 permit issuing authority must require an applicant to 34 file a copy of a notice of commencement; revising the 35 definition of the term “copy of the notice of 36 commencement”; revising the information that must be 37 included in a notice of commencement; requiring that a 38 permit application be signed by the property owner in 39 certain circumstances; revising the form of a building 40 permit application; providing an effective date. 41 42 Be It Enacted by the Legislature of the State of Florida: 43 44 Section 1. Paragraph (b) of subsection (2) of section 45 455.2124, Florida Statutes, is amended to read: 46 455.2124 Proration of or not requiring continuing 47 education.— 48 (2) 49 (b) This subsection does not apply to building code 50 administrators and inspectors regulated pursuant to part XII of 51 chapter 468; engineers regulated pursuant to chapter 471; to 52 certified public accountants regulated pursuant to chapter 473; 53 to brokers, broker associates, and sales associates regulated 54 pursuant to part I of chapter 475; to appraisers regulated 55 pursuant to part II of chapter 475; to architects, interior 56 designers, or landscape architects regulated pursuant to chapter 57 481; or to contractors regulated pursuant to chapter 489. 58 Section 2. Subsection (2) and paragraph (h) of subsection 59 (5) of section 468.603, Florida Statutes, are amended, and 60 paragraph (e) is added to subsection (8) of that section, to 61 read: 62 468.603 Definitions.—As used in this part: 63 (2) “Building code administrator” or “building official” 64 means any of those employees of municipal or county governments, 65 or any person contracted, with building construction regulation 66 responsibilities who are charged with the responsibility for 67 direct regulatory administration or supervision of plan review, 68 enforcement, or inspection of building construction, erection, 69 repair, addition, remodeling, demolition, or alteration projects 70 that require permitting indicating compliance with building, 71 plumbing, mechanical, electrical, gas, fire prevention, energy, 72 accessibility, and other construction codes as required by state 73 law or municipal or county ordinance. This term is synonymous 74 with “building official” as used in the Florida Building Code. 75 One person employed or contracted by each municipal or county 76 government as a building code administrator or building official 77 and who is so certified under this part may be authorized to 78 perform any plan review or inspection for which certification is 79 required by this part, including performing any plan review or 80 inspection as a currently designated standard certified building 81 official under an interagency service agreement with a 82 jurisdiction having a population of 50,000 or less or with a 83 state university, Florida College System institution, or school 84 district with an enrollment of 50,000 or less. 85 (5) “Categories of building code inspectors” include the 86 following: 87 (h) “Residential inspector” means a person who is qualified 88 to inspect and determine whether detached that one-family and, 89 two-family, or three-family residences and townhomes not 90 exceeding three stories above grade plane in height with a 91 separate means of egress, not exceeding two habitable stories 92 above no more than one uninhabitable story and, in connection 93 therewith, accessory use structures not exceeding three stories 94 above grade plane, in connection therewith are constructed in 95 accordance with the provisions of the governing building, 96 plumbing, mechanical, accessibility, and electrical codes. 97 (8) “Plans examiner” means a person who is qualified to 98 determine that plans submitted for purposes of obtaining 99 building and other permits comply with the applicable building, 100 plumbing, mechanical, electrical, gas, fire prevention, energy, 101 accessibility, and other applicable construction codes. The term 102 includes a residential plans examiner who is qualified to 103 determine that plans submitted for purposes of obtaining 104 building and other permits comply with the applicable 105 residential building, plumbing, mechanical, electrical, gas, 106 energy, accessibility, and other applicable construction codes. 107 Categories of plans examiners include: 108 (e) Residential plans examiner. 109 Section 3. Paragraph (b) of subsection (10) of section 110 468.609, Florida Statutes, is amended to read: 111 468.609 Administration of this part; standards for 112 certification; additional categories of certification.— 113 (10) 114 (b) The board shall by rule establish: 115 1. Reciprocity of certification with any other state that 116 requires an examination administered by the International Code 117 Council. 118 2. That an applicant for certification as a building code 119 inspector or plans examiner may apply for a provisional 120 certificate valid for the duration of the internship period. 121 3. That partial completion of an internship program is 122 transferable among jurisdictions, private providers, and firms 123 of private providers on a form prescribed by the board. 124 4. That an applicant may apply for a standard certificate 125 on a form prescribed by the board upon successful completion of 126 an internship certification program. 127 5. That an applicant may apply for a standard certificate 128 at least 30 days but no more than 60 days before completing the 129 internship certification program. 130 6. That a building code inspector or plans examiner who has 131 standard certification may seek an additional certification in 132 another category by completing an additional nonconcurrent 1 133 year internship program in the certification category sought and 134 passing an examination administered by the International Code 135 Council and a board-approved 40-hour code training course. 136 7. A residential inspector internship program, with the 137 following requirements: 138 a. An enrollee must hold an International Code Council 139 certification, or a legacy certification for one- and two-family 140 dwelling inspectors issued by an industry-recognized equivalent 141 organization, as a residential or commercial inspector in the 142 building, electrical, plumbing, and mechanical categories before 143 beginning the internship program, and must: 144 (I) Complete 1 year of on-the-job training in each of the 145 building, electrical, plumbing, and mechanical categories, under 146 the supervision of a standard certified inspector. Previous 147 verifiable experience that includes at least 6 months of on-the 148 job training in a single category under the supervision of a 149 standard certified inspector may be counted toward the required 150 training in that category; however, previously completed 151 training may not substitute for more than 2 years of the total 152 on-the-job training required under this sub-sub-subparagraph; or 153 (II) Hold a standard certification as an inspector in a 154 category listed in s. 468.603(5) and complete at least 6 months 155 of on-the-job training under the supervision of a standard 156 certified inspector in each of the following categories in which 157 the enrollee does not hold a standard certification: 158 (A) Building. 159 (B) Plumbing. 160 (C) Electrical. 161 (D) Mechanical. 162 b. The completion of an 80-hour residential inspector code 163 training course. 164 8. A residential plans examiner internship program, with 165 the following requirements: 166 a. An enrollee must hold an International Code Council 167 certification as a residential or commercial plans examiner in 168 the building, electrical, plumbing, and mechanical categories 169 before beginning the internship program, and must: 170 (I) Complete 1 year of on-the-job training in each of the 171 building, electrical, plumbing, and mechanical categories, under 172 the supervision of a standard certified plans examiner; or 173 (II) Hold a standard certification as a plans examiner in a 174 category listed in s. 468.603(5) and complete at least 1 year of 175 on-the-job training under the supervision of a standard 176 certified plans examiner in each of the following categories in 177 which the enrollee does not hold a standard certification: 178 (A) Building. 179 (B) Plumbing. 180 (C) Electrical. 181 (D) Mechanical. 182 b. The completion of a 40-hour residential plans examiner 183 code training course. 184 9. A roofing inspector internship program, with the 185 following requirements: 186 a. An enrollee must hold an International Code Council 187 certification as a roofing inspector in this state before 188 beginning the internship program, and must: 189 (I) Complete 1 year of on-the-job training as a roofing 190 inspector under the supervision of a standard certified 191 commercial building inspector or roofing inspector; or 192 (II) Hold a standard certification as a residential 193 building inspector and complete at least 200 hours of on-the-job 194 training under the supervision of a standard certified 195 commercial building inspector or roofing inspector. 196 b. The completion of a 40-hour roofing inspector code 197 training course. 198 10. The following eligibility criteria for one- and two 199 family dwelling inspector certifications: 200 a. Completion of a residential inspector internship 201 program; or 202 b. Completion of a residential plans examiner internship 203 program. 204 11. An application process for qualified candidates which 205 includes the voluntary certification categories created by the 206 board pursuant to paragraph (a) on provisional certification 207 application forms. 208 Section 4. Paragraph (c) of subsection (7) of section 209 489.103, Florida Statutes, is amended to read: 210 489.103 Exemptions.—This part does not apply to: 211 (7) 212 (c) To qualify for exemption under this subsection, an 213 owner or, for an owner that is a corporate entity, the owner’s 214 agent must personally or virtually appear and sign the building 215 permit application and disclosure statement and must satisfy 216 local permitting agency requirements, if any, proving that the 217 owner has a complete understanding of the owner’s obligations 218 under the law as specified in the disclosure statement in this 219 section. However, for purposes of implementing a “United States 220 Department of Energy SunShot Initiative: Rooftop Solar 221 Challenge” grant and the participation of county and municipal 222 governments, including local permitting agencies under the 223 jurisdiction of such county and municipal governments, an 224 owner’s notarized signature or personal appearance to sign the 225 permit application is not required for a solar project, as 226 described in subparagraph (a)3., if the building permit 227 application is submitted electronically to the permitting agency 228 and the owner certifies the application and disclosure statement 229 using the permitting agency’s electronic confirmation system. If 230 any person violates the requirements of this subsection, the 231 local permitting agency shall withhold final approval, revoke 232 the permit, or pursue any action or remedy for unlicensed 233 activity against the owner and any person performing work that 234 requires licensure under the permit issued. The local permitting 235 agency shall provide the person with a disclosure statement in 236 substantially the following form: 237 238 DISCLOSURE STATEMENT 239 240 1. I understand that state law requires construction 241 to be done by a licensed contractor and have applied 242 for an owner-builder permit under an exemption from 243 the law. The exemption specifies that I, as the owner 244 of the property listed, may act as my own contractor 245 with certain restrictions even though I do not have a 246 license. 247 248 2. I understand that permit applications building 249 permits are not required to be signed by a property 250 owner when unless he or she is responsible for the 251 construction and is not hiring a licensed contractor 252 to assume responsibility; when hiring a contractor 253 under a direct contract of greater than $7,500; or 254 when repairing or replacing an existing heating or 255 air-conditioning system under a direct contract of 256 $15,000 or greater. 257 258 3. I understand that, as an owner-builder, I am the 259 responsible party of record on a permit. I understand 260 that I may protect myself from potential financial 261 risk by hiring a licensed contractor and having the 262 permit filed in his or her name instead of my own 263 name. I also understand that a contractor is required 264 by law to be licensed in Florida and to list his or 265 her license numbers on permits and contracts. 266 267 4. I understand that I may build or improve a one 268 family or two-family residence or a farm outbuilding. 269 I may also build or improve a commercial building if 270 the costs do not exceed $75,000. The building or 271 residence must be for my own use or occupancy. It may 272 not be built or substantially improved for sale or 273 lease, unless I am completing the requirements of a 274 building permit where the contractor listed on the 275 permit substantially completed the project. If a 276 building or residence that I have built or 277 substantially improved myself is sold or leased within 278 1 year after the construction is complete, the law 279 will presume that I built or substantially improved it 280 for sale or lease, which violates the exemption. 281 282 5. I understand that, as the owner-builder, I must 283 provide direct, onsite supervision of the 284 construction. 285 286 6. I understand that I may not hire an unlicensed 287 person to act as my contractor or to supervise persons 288 working on my building or residence. It is my 289 responsibility to ensure that the persons whom I 290 employ have the licenses required by law and by county 291 or municipal ordinance. 292 293 7. I understand that it is a frequent practice of 294 unlicensed persons to have the property owner obtain 295 an owner-builder permit that erroneously implies that 296 the property owner is providing his or her own labor 297 and materials. I, as an owner-builder, may be held 298 liable and subjected to serious financial risk for any 299 injuries sustained by an unlicensed person or his or 300 her employees while working on my property. My 301 homeowner’s insurance may not provide coverage for 302 those injuries. I am willfully acting as an owner 303 builder and am aware of the limits of my insurance 304 coverage for injuries to workers on my property. 305 306 8. I understand that I may not delegate the 307 responsibility for supervising work to a licensed 308 contractor who is not licensed to perform the work 309 being done. Any person working on my building who is 310 not licensed must work under my direct supervision and 311 must be employed by me, which means that I must comply 312 with laws requiring the withholding of federal income 313 tax and social security contributions under the 314 Federal Insurance Contributions Act (FICA) and must 315 provide workers’ compensation for the employee. I 316 understand that my failure to follow these laws may 317 subject me to serious financial risk. 318 319 9. I agree that, as the party legally and financially 320 responsible for this proposed construction activity, I 321 will abide by all applicable laws and requirements 322 that govern owner-builders as well as employers. I 323 also understand that the construction must comply with 324 all applicable laws, ordinances, building codes, and 325 zoning regulations. 326 327 10. I understand that I may obtain more information 328 regarding my obligations as an employer from the 329 Internal Revenue Service, the United States Small 330 Business Administration, the Florida Department of 331 Financial Services, and the Florida Department of 332 Revenue. I also understand that I may contact the 333 Florida Construction Industry Licensing Board at 334 ...(telephone number)... or ...(Internet website 335 address)... for more information about licensed 336 contractors. 337 338 11. I am aware of, and consent to, an owner-builder 339 building permit applied for in my name and understand 340 that I am the party legally and financially 341 responsible for the proposed construction activity at 342 the following address: ...(address of property).... 343 344 12. I agree to notify ...(issuer of disclosure 345 statements)... immediately of any additions, 346 deletions, or changes to any of the information that I 347 have provided on this disclosure. 348 349 Licensed contractors are regulated by laws designed to 350 protect the public. If you contract with a person who 351 does not have a license, the Construction Industry 352 Licensing Board and Department of Business and 353 Professional Regulation may be unable to assist you 354 with any financial loss that you sustain as a result 355 of a complaint. Your only remedy against an unlicensed 356 contractor may be in civil court. It is also important 357 for you to understand that, if an unlicensed 358 contractor or employee of an individual or firm is 359 injured while working on your property, you may be 360 held liable for damages. If you obtain an owner 361 builder permit and wish to hire a licensed contractor, 362 you will be responsible for verifying whether the 363 contractor is properly licensed and the status of the 364 contractor’s workers’ compensation coverage. 365 366 Before a building permit can be issued, this 367 disclosure statement must be completed and signed by 368 the property owner and returned to the local 369 permitting agency responsible for issuing the permit. 370 A copy of the property owner’s driver license, the 371 notarized signature of the property owner, or other 372 type of verification acceptable to the local 373 permitting agency is required when the permit is 374 issued. 375 376 Signature: ...(signature of property owner).... 377 Date: ...(date).... 378 379 Section 5. Subsection (4) is added to section 489.1195, 380 Florida Statutes, to read: 381 489.1195 Responsibilities.— 382 (4)(a) When a business organization designates a new 383 qualifying agent, the new qualifying agent must apply to the 384 department for a change of contractor within 90 days after 385 designation in each jurisdiction in which an active permit is 386 held by the business organization’s previous qualifying agent. 387 (b) Upon request of a city or county building department 388 official, the business organization may sign a change of 389 contractor form provided by such official for the purpose of 390 withdrawing the business organization’s previous qualifying 391 agent as the holder of an active or expired building permit. If 392 the previous qualifying agent who obtained the permit declines 393 to withdraw, is unavailable, or is deceased, the owner of the 394 project for which the permit was issued may serve a notice of 395 change of contractor to the previous qualifying agent at his or 396 her last known mailing or e-mail address and, after providing 397 such notice, must submit a change of contractor form to the 398 building department official along with a hold harmless 399 affidavit in the form specified by the board. Upon receipt of 400 the hold harmless affidavit, the building department official 401 shall process the change of contractor to designate a new 402 qualifying agent without requiring a notification or waiting 403 period. 404 (c) A qualifying agent designated through a change of 405 contractor process pursuant to paragraph (b) is not responsible 406 for his or her predecessor’s work but is responsible for any 407 corrective work performed on his or her predecessor’s work. 408 Section 6. Paragraph (e) of subsection (1) and paragraph 409 (a) of subsection (7) of section 713.135, Florida Statutes, are 410 amended, and paragraph (g) is added to subsection (1) of that 411 section, to read: 412 713.135 Notice of commencement and applicability of lien.— 413 (1) When a person applies for a building permit, the 414 authority issuing such permit shall: 415 (e) Require the applicant to file with the issuing 416 authority before the first inspection a copy of the notice of 417 commencement if the direct contract is greater than $7,000 418 $5,000. For purposes of this paragraph, the term “copy of the 419 notice of commencement” means a certified copy of the recorded 420 notice of commencement, a notarized statement that the notice of 421 commencement has been filed for recording along with a copy 422 thereof, or the clerk’s office’s official records identifying 423 information that includes the instrument number for the notice 424 of commencement or the number and page of book where the notice 425 of commencement is recorded, as identified by the clerk. 426 1. In the absence of the filing of a copy of the notice of 427 commencement, the issuing authority or a private provider 428 performing inspection services may not perform or approve 429 subsequent inspections until the applicant files by mail, 430 facsimile, hand delivery, or any other means such copy with the 431 issuing authority. 432 2. The copy of the notice of commencement must contain the 433 name and address of the owner, the name and address of the 434 contractor, and the location or address of the property being 435 improved, and a general description of the improvement. The 436 issuing authority shall verify that the name and address of the 437 owner, the name of the contractor, and the location or address 438 of the property being improved, and the general description of 439 the improvement which is contained in the copy of the notice of 440 commencement are is consistent with the information in the 441 building permit application. 442 3. The issuing authority shall provide the recording 443 information on the copy of the notice of commencement to any 444 person upon request. 445 4. This paragraph does not require the recording of a 446 notice of commencement before the issuance of a building permit. 447 If a local government requires a separate permit or inspection 448 for installation of temporary electrical service or other 449 temporary utility service, land clearing, or other preliminary 450 site work, such permits may be issued and such inspections may 451 be conducted without providing the issuing authority with a copy 452 of the notice of commencement. 453 (g) A permit application must be signed by the owner of the 454 real property when the direct contract between the contractor 455 and such owner is greater than $7,500 or, if repairing or 456 replacing an existing heating or air-conditioning system, when 457 the direct contract between the contractor and such owner is 458 $15,000 or greater. 459 460 This subsection does not apply to a direct contract to repair or 461 replace an existing heating or air-conditioning system in an 462 amount less than $15,000. 463 (7)(a) In addition to any other information required by the 464 authority issuing the permit, the building permit application 465 must be in substantially the following form: 466 467 Tax Folio No......... 468 BUILDING PERMIT APPLICATION 469 470 Owner’s Name.................................................... 471 Owner’s Address................................................. 472 Fee Simple Titleholder’s Name (If other than owner)............. 473 Fee Simple Titleholder’s Address (If other than owner).......... 474 City............................................................ 475 State............ Zip............ 476 Contractor’s Name............................................... 477 Contractor’s Address............................................ 478 City............................................................ 479 State............ Zip............ 480 Job Name........................................................ 481 Job Address..................................................... 482 City................ County............ 483 Legal Description............................................... 484 Bonding Company................................................. 485 Bonding Company Address......................................... 486 City................ State............ 487 Architect/Engineer’s Name....................................... 488 Architect/Engineer’s Address.................................... 489 Mortgage Lender’s Name.......................................... 490 Mortgage Lender’s Address....................................... 491 492 Application is hereby made to obtain a permit to do the 493 work and installations as indicated. I certify that no work or 494 installation has commenced prior to the issuance of a permit and 495 that all work will be performed to meet the standards of all 496 laws regulating construction in this jurisdiction. I understand 497 that a separate permit must be secured for ELECTRICAL WORK, 498 PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, 499 TANKS, and AIR CONDITIONERS, etc., when required by this 500 jurisdiction. 501 502 OWNER’S AFFIDAVIT: I certify that all the foregoing information 503 is accurate and that all work will be done in compliance with 504 all applicable laws regulating construction and zoning. 505 506 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF 507 COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR 508 IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF 509 COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB 510 SITE BEFORE THE FIRST INSPECTION. 511 512 IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR 513 LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR 514 RECORDING YOUR NOTICE OF COMMENCEMENT. 515 516 ...(Signature of Owner or Agent)... 517 518 ...(including contractor)... 519 520 STATE OF FLORIDA 521 COUNTY OF .... 522 523 Sworn to (or affirmed) and subscribed before me this .... 524 day of ...., ...(year)..., by ...(name of person making 525 statement).... 526 527 ...(Signature of Notary Public - State of Florida)... 528 ...(Print, Type, or Stamp Commissioned Name of Notary Public)... 529 530 Personally Known .... OR Produced Identification .... 531 532 Type of Identification Produced............ 533 ...(Signature of Contractor)... 534 535 STATE OF FLORIDA 536 COUNTY OF .... 537 538 Sworn to (or affirmed) and subscribed before me this .... 539 day of ...., ...(year)..., by ...(name of person making 540 statement).... 541 ...(Signature of Notary Public - State of Florida)... 542 ...(Print, Type, or Stamp Commissioned Name of Notary Public)... 543 544 Personally Known .... OR Produced Identification .... 545 546 Type of Identification Produced............ 547 548 (Certificate of Competency Holder) 549 550 Contractor’s State Certification or Registration No..... 551 552 Contractor’s Certificate of Competency No......... 553 554 APPLICATION APPROVED BY 555 ................Permit Officer 556 557 Section 7. This act shall take effect July 1, 2025.

Official text from the Florida Legislature. Formatting has been adapted for reading on Ratifi.